Klipper deploy probe - RRF employs a ‘probe deployed token’ and thus, if a gcode issued that relies on probe deployment, the system will deploy and retract it automatically. If a series of probing commands is desired, then it is recommended that and M401 and M402 pair bracket the sequence of gcodes. See the example homez.g and bed4point.g macros for …

 
The probe_calibrate KINDA WORKS - ONLY via utilization of the 1mm increment in the “advanced” options, the micro increments don’t work. I’m guessing maybe its’ something from the sensorless homing capabilities of the 2209’s on the mini e3v3 board and how those blue bottons are configured compared to the “advanced” buttons, but .... 5below hours

Send: BED_MESH_CALIBRATE Recv: // Failed to home probe: Timeout during endstop homing Recv: // Make sure to home the printer before probing. If the probe Recv: // did not move far enough to trigger, then consider reducing Recv: // the Z axis minimum position so the probe can travel further Recv: // (the Z minimum position can …Jun 10, 2019 · Hi @Ladrogue,. It did not look like there was a Klipper log file attached to this ticket. The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions). With the advent of 5G technology, people around the world are eagerly anticipating the lightning-fast speeds and low latency that this next-generation network promises to deliver. To understand where 5G towers are located, it’s important to...May 31, 2021 · Getting Klipper setup on Ender 3 with 4.2.7 board and BLTouch 3.1. I am having trouble with the bltouch when homing. It will move to start homing and then probe wont deploy at all. I get a message of “Endstop z still triggered after retract” I’ve tried going through steps on this site (Connecting BL-Touch | klipper) but didnt work. Wires ... May 6, 2021 · And the [probe] section: [probe] pin: ^your_pin_here x_offset: your_offset y_offset: your_offset z_offset: your_offset speed: 5.0 I just wonder how to reliably determine the offsets with this kind of probe. For z_offset probably 0,0 but the rest looks tricky. To verify the probe is working I’d recommend: Move the bed away from the tool-head ... Problem with "BL touch failed to raise probe" error - redux · Issue #3605 · Klipper3d/klipper · GitHub WizardOfYendor1 commented on Dec 5, 2020 I having the exact same problem again, randomly, as documented in issue #2848. What's changed since the last time is I decided I was getting too far behind on updates and I updated the firmware and...OR, the better way, fix the "QUERY_PROBE" command so it retain the "TRIGGERED" state until the probe pin goes down. Maybe, if you can't retain the triggered state, then add a command that will wait for the probe to be triggered, and then send that message on console. Don't forget to fix the documentation for the Bl-Touch tests too.There is no deploy probe command that he can use for this. Oh, wow, ok. Well in that case put the probe in place, run a BED_MESH_CALIBRATE then run BED_MESH_PROFILE SAVE=name to save a mesh profile. Then in your start gcode or in your Gcode Macro Start_Print after G28 add BED_MESH_PROFILE LOAD=name and it will load the saved mesh.BL Touch V3.1 Start up = klick klack red led I can run commands pin_down / pin_up / self_test so everything looks OK G28 with printhead in position probe goes down (blue) then up (red) and after that nothing happens parts from my log file (as a whole log can not be uploaded) [bltouch] sensor_pin = ar2 control_pin = ar6 x_offset = -39.1 y_offset = 0 speed = 15.0 samples = 2 sample_retract_dist ...did the BLTouch tests, failed at this point: " The next step is to confirm that the sensor pin is working correctly. Run BLTOUCH_DEBUG COMMAND=pin_down, verify that the pin moves down, run BLTOUCH_DEBUG COMMAND=touch_mode, run QUERY_PROBE, and verify that command reports “probe: open”. Then while gently pushing the pin up slightly with the ...May 8, 2020 · I've seen similar deploy / retract issues on 5 different printers (using different firmwares & versions, including Marlin v1 & 2 ) and all of them were using a clone - usually labelled 3Dtouch. Microprobe klipper issue ... 3 samples_tolerance: 0.01 samples_tolerance_retries: 5 activate_gcode: _Probe_Deploy G4 P500 # Allow 500 milliseconds for probe deploy ...A quick guide on setting your probes Z offset in Klipper. Code: PROBE_CALIBRATE TESTZ Z= Further reading: https://www.klipper3d.org/ …Hi @gcurtis79,. It did not look like there was a Klipper log file attached to this ticket. The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions).The Ender 3 Max uses the same board and also has the CR-Touch. A verified cfg can be found here: klipper/printer-creality-ender3max-2021.cfg at master · Klipper3d/klipper · GitHub Edit: Also make sure that your bed is sufficiently far away so that the probe can actually deploy.After testing my 3dtouch with BLtouch debug commands and confirming the board is reading the control pin proper I try to run G28 to home the bed. the problem is …maybe too many asked but i've stacked here. bltouch commands work (pindown, pinup, self_test, reset) but when homing it's failed to deploy. cables are ok updates installed (also fresh install with new sd) any suggestions? "and how to add klippy.log :D" 16:59:30 $ FIRMWARE_RESTART 16:59:38 // Failed to verify BLTouch probe is raised; retrying ...Microprobe klipper issue ... 3 samples_tolerance: 0.01 samples_tolerance_retries: 5 activate_gcode: _Probe_Deploy G4 P500 # Allow 500 milliseconds for probe deploy ... Probing questions provide a deeper understanding of an issue or topic. This type of question encourages reflection, aids in the creation of a paradigm shift and allows for multiple responses.There is no deploy probe command that he can use for this. Oh, wow, ok. Well in that case put the probe in place, run a BED_MESH_CALIBRATE then run BED_MESH_PROFILE SAVE=name to save a mesh profile. Then in your start gcode or in your Gcode Macro Start_Print after G28 add BED_MESH_PROFILE LOAD=name and it will load the saved mesh.Microprobe klipper issue ... 3 samples_tolerance: 0.01 samples_tolerance_retries: 5 activate_gcode: _Probe_Deploy G4 P500 # Allow 500 milliseconds for probe deploy ... I had to adjust the tiny screw at one point because it was unreliably deploying/stowing. It's through the hole in the back and I don't recall which direction does what unfortunately. The screw is the way the magnet holds the probe so it may be holding too tight to deploy. Has this probe worked for you in the past on a Marlin setup perhaps? We have broken the klipper setup into two parts- the general hardware configuration in the printer.cfg to be consistent with all hardware definitions and a pointer in the printer.cfg to include the …if trying to deploy/retract the probe through the lcd menu doesn't work and M119 and M280 P0 S90 commands don't work then marlin can't control it at all, meaning either the wiring or basic setup is probably not right, and not a specific problem with homing. the deploy/retract when it powers up just means it got power, which happens even if the ...Recv: // Failed to verify BLTouch probe is raised; retrying. Recv: // Klipper state: Ready 4- To exit this state, I have to send G28. Issue 3 - Sometimes the probe does not go down. I'm not sure this is an issue with Klipper or with my 3dtouch, but sometimes, when I try to home, the probe pin does not go down and the home command does not …Join us on our step by step tutorial when we install BL Touch on our Ender 3V2 that running Klipper. 00:00 Introduction01:06 Recap01:48 Printer.cfg13:54 Buil...Welcome. Klipper is a 3d-Printer firmware. It combines the power of a general purpose computer with one or more micro-controllers. See the features document for more information on why you should use Klipper. To begin using Klipper start by installing it. Klipper is Free Software. Read the documentation or view the Klipper code on github .The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions). Unfortunately, too many people have opened tickets without providing the log.Mar 28, 2020 · did the BLTouch tests, failed at this point: " The next step is to confirm that the sensor pin is working correctly. Run BLTOUCH_DEBUG COMMAND=pin_down, verify that the pin moves down, run BLTOUCH_DEBUG COMMAND=touch_mode, run QUERY_PROBE, and verify that command reports “probe: open”. Then while gently pushing the pin up slightly with the ... im havving an issue with trying to get the BL touch to work, i can get it to deploy and back it come back up, but if i try to auto home i have the error: Recv: !! BLTouch failed to deploy Recv: // Failed to verify BLTouch probe is raised; retrying. Recv: // Failed to verify BLTouch probe is raised; retrying.Hello everyone, I have been having a issue with my BL Touch since I have started using Klipper. When I start a print and when it goes through the probing process it will fail saying the probe was not triggered. I have to restart the print 2 - 3 times before it makes through the 9 points successfully. Here is my config: [bltouch] sensor_pin: ^PA7.Nov 28, 2022 · Probe takes a while to trigger/nozzle crashes into bed before probe can trigger but the probe does still trigger the probe tip needs adequate space to be able to probe. Generally the distance in height from the tip of the probe to the tip of the nozzle should be within 2.3-4.3mm If there is not enough clearance the probe will not activate in ... In case anyone comes here in the future my problem was that Klipper was preventing my stepper_z and stepper_z1 from going below zero. I had to include... position_min: -5 # Needed for z-offset calibration and tilt_adjust. ... CR-Touch (Bltouch) won’t deploy probe - errors with “failed to verify sensor state” with dual carriage enabled ...In case anyone comes here in the future my problem was that Klipper was preventing my stepper_z and stepper_z1 from going below zero. I had to include... position_min: -5 # Needed for z-offset calibration and tilt_adjust. This did the trick!A quick guide on setting your probes Z offset in Klipper.Code:PROBE_CALIBRATETESTZ Z=Further reading: https://www.klipper3d.org/https://www.klipper3d.org/Bed...The probe deploy and stow using debug commands, BLTOUCH_DEBUG COMMAND=pin_down, BLTOUCH_DEBUG COMMAND=pin_up, and report the output triggered or open when commands BLTOUCH_DEBUG COMMAND=touch_mode and QUERY_PROBE but using homing button fail to deploy the stroke, I can see the blue led flashing but nothing happen, the stroke does not deploy.Jul 28, 2021 · A quick guide on the basic settings for a BLTouch probe.Code: If removing the Z endstop switch and just using the BLTouch, you will need to change one line u... Before the testing may begin, be sure to Home your printer using the Home icon under the Controls tab. For Pulse users: Navigate to the Controls tab and then the Macros section, then click the Deploy Probe button. Check the BLTouch to see if the Flag (Probe leg) deployed (extended downward). If the Flag did not deploy, then you will want to ...Hi, I have been printing using marlin for a couple of months now with no major issues. I figured I would give Klipper a try to further optimize my prints. When I got to the part of the guide regarding bltouch I began experiencing errors The Issue: When I type query_probe into the terminal klipper invariably returns : // probe: TRIGGERED Raising, lowering, and resetting has no effect on this ...These same offsets worked in my prior configuration where I used a Duet Wifi (without klipper). I re-measured them based on Kevin's guide and they are the same offsets.... What is also weird is if I move the nozzle to X0,Y0, and then do a 'probe', the result comes back saying my probe is at 0,0.Probe takes a while to trigger/nozzle crashes into bed before probe can trigger but the probe does still trigger the probe tip needs adequate space to be able to probe. Generally the distance in height from the tip of the probe to the tip of the nozzle should be within 2.3-4.3mm If there is not enough clearance the probe will not activate in ...Welcome. Klipper is a 3d-Printer firmware. It combines the power of a general purpose computer with one or more micro-controllers. See the features document for more information on why you should use Klipper. To begin using Klipper start by installing it. Klipper is Free Software. Read the documentation or view the Klipper code on github .Whenever I try to do a mesh calibration, the printer starts probing as it should but in the first couple of probes it will fail to deploy the probe. When I change the probing to use stow_on_each_sample=false and probe_with_touch_mode: true as a workaround the probe will fail to trigger a couple of probes into the mesh. The number …when I test the probe with debug commands, the probe deploy and stow the pin but when the pin is deployed, the z endstop is shown as triggered. Using a bltouch …Adjusting bed leveling screws using the bed probe¶ This is another way to calibrate the bed level using the bed probe. To use it you must have a Z probe (BL Touch, Inductive sensor, etc). To enable this feature, one would determine the nozzle coordinates such that the Z probe is above the screws, and then add them to the config file.For reference, when the probe is at mesh_min the nozzle will be at (11, 1), and when the probe is at mesh_max, the nozzle will be at (206, 193). Round beds¶ This example assumes a printer equipped with a round bed radius of 100mm. We will use the same probe offsets as the rectangular example, 24 mm on X and 5 mm on Y.I have an issue with BLTOUCH v3.1 (genuine) on SKR3 EZ mainboard, attached log and cfg files. The probe deploy and stow using debug commands, BLTOUCH_DEBUG COMMAND=pin_down, BLTOUCH_DEBUG COMMAND=pin_up, and report the output triggered or open when commands BLTOUCH_DEBUG …Hello, I recently introduced a fourth z axis to my printer (prior it had 3). After adding the fourth z to my printer.cfg and z_tilt section the Z_TILT_ADJUST macro is acting up. The z position just is not being corrected. It keeps staying at around the same value (0.4) and stops after the retry counter/slight increase.There is no deploy probe command that he can use for this. Oh, wow, ok. Well in that case put the probe in place, run a BED_MESH_CALIBRATE then run BED_MESH_PROFILE SAVE=name to save a mesh profile. Then in your start gcode or in your Gcode Macro Start_Print after G28 add BED_MESH_PROFILE LOAD=name and it will load the saved mesh.First run BLTOUCH_DEBUG COMMAND=pin_down in your printer terminal. Verify that the pin moves down, and that the red LED on the probe turns off. If not, check your wiring and configuration again. Next issue a BLTOUCH_DEBUG COMMAND=pin_up, verify that the pin moves up, and that the red light turns on again. If it's flashing then there's some problem.Klipper BL Touch Problem. I have the Duet WiFi and Duex5 boards. I've installed Klipper and everything works except the bl touch. The bl touch does its system check moving up and down and I have a solid red light. The debug pin down command doesn't move the pin down. Pushing the pin up or down the probe query shows it as open for both.Examples of probing questions are: “What happened next?” “What would you do differently next time?” “How did you feel about that?” “What was your actual role in that?” “Why did you choose that method?” Probing questions are open-ended quest...Welcome. Klipper is a 3d-Printer firmware. It combines the power of a general purpose computer with one or more micro-controllers. See the features document for more …I received my Euclid Probe a week or so ago to replace a failing inductive probe. It is installed on a Voron 2.4 Fysetc Spider 1.1 running Klipper and OctoPrint. I've printed out the parts and installed the probe using the same wiring and Fysetc port (pin PA3) that I was using for the inductive probe Unfortunatly, after loading euclid.cfg, I've ... Try better after each configuration-change the homing itself. So that the printer does not drive into the bed, you can trigger the bltouch much earlier with your finger. If the printer does not stop, then quickly disconnect the power supply. 2. pietchaki • 2 yr. ago.Sign in . I have a Kossel Delta, had the (original) BLTouch 3.1 working perfectly under Marlin. I have klipper working fine, the BLTouch probe goes up and …CR Touch fails to deploy but it isn't really failed? I recently updated Klipper and now running on v0.10.0-278-g7c964e5f. My CR Touch no longer seems to work properly when trying to calibrate. When you run the calibration it will probe the first, second, and third spot but will always fail on the 4th each time.And for the sake of completeness, (on my printer) the probe is mounted to the extruder, not fixed to the bed. In Marlin I understand it like this: Probe is triggered, z_offset equivalent says "hey nozzle, you'll find Z=0 now 2.134 mm underneath". Is it the same for Klipper?A spare Allen key is used with an endstop switch to make a probe that’s deployed and stowed by turning the key 90 degrees. You can either deploy and stow the key manually or configure movements that bump the key against some fixed point. Options for this type of probe are included in the delta example configurations that come with Marlin.This doesn't sound like a BLTouch issue to me. When I faced similar issues, one of the below fixed it: Use the paper method to level the bed initially and then attempt to calculate the probe Z-offset. Tighten the Eccentric Nut on the bed. I found that my bed had minor wobble, so leveling kept giving me random results.Learn how to calibrate the X, Y, and Z offsets of an automatic z probe in Klipper using the PROBE_CALIBRATE tool. Find out how to check the repeatability, location, and temperature of the probe results and how to adjust the probe speed and samples count.Feb 28, 2017 · Jean-Fred-CEC commented on Feb 28, 2017 •edited by thinkyhead. Hi everybody, I updated the last marlin firmware (1.1.0) in my home made 3D printer and I don't know how to reduce the height that my probe raise between each probe point. These macros are based on the great Annex magprobe dockable probe macros \"#Originally developed by Mental, modified for better use on K-series printers by RyanG and Trails\", kudos to them.\nThat macro as since evolved into a klipper plugin that currently is pending inclusion in klipper, more information hereWe have broken the klipper setup into two parts- the general hardware configuration in the printer.cfg to be consistent with all hardware definitions and a pointer in the printer.cfg to include the euclid.cfg file for the macros. Please look at both parts. Probe device configurationA quick guide on setting your probes Z offset in Klipper. Code: PROBE_CALIBRATE TESTZ Z= Further reading: https://www.klipper3d.org/ …Ender 3 V2 4.2.2 mainboard CR touch probe does not deploy. Z axis won't home. I have installed the probe and updated to the correct (4.2.2 with the probe) firmware, however when I try to home the Z axis it just moves up and sits there and the CR probe does not deploy. The Z axis limit switch is unplugged and there is a red led flickering inside ...And the [probe] section: [probe] pin: ^your_pin_here x_offset: your_offset y_offset: your_offset z_offset: your_offset speed: 5.0 I just wonder how to reliably determine the offsets with this kind of probe. For z_offset probably 0,0 but the rest looks tricky. To verify the probe is working I’d recommend: Move the bed away from the tool-head ...Nov 19, 2021 · JJPrinsloo commented on Nov 19, 2021. 👍 1. Verify wiring. Use different sensor pins. Usually endstop pins will work. Try with pull-up (^) or without for the sensor pin. Maybe obvious: Make sure then pin does not hit the bed during the BLTouch startup sequence. Startup issue. In the Settings tab, navigate to the "Behavior" sub-tab and select the "Cancel any ongoing prints but stay connected to the printer" option. Click "Save". From the main page, under the "Connection" section (at the top left of the page) make sure the "Serial Port" is set to "/tmp/printer" and click "Connect". Jul 28, 2021 · A quick guide on the basic settings for a BLTouch probe.Code: If removing the Z endstop switch and just using the BLTouch, you will need to change one line u... when I test the probe with debug commands, the probe deploy and stow the pin but when the pin is deployed, the z endstop is shown as triggered. Using a bltouch 3.1 genuine also, it does not work with probe_with_touch_mode: True neither false any clue? attached log and printer config, klipper version on mcu v0.10.-554-g9e4994cb klippy.log (114. ...I have waited now two days and I just tried the M401 and M402 and M280 commands and the BLTouch is not responding. Here is my firmware config. Board: Duet 3 MB6HC (MB6HC) DSF Version: 1.2.4.0. Firmware: RepRapFirmware for Duet 3 MB6HC v0.6 or 1.0 3.0 (2020-01-03b3. Here is the probe portion of my config.g. ; Z-Probe.My Ender3 S1 Pro was working with Klipper and then suddenly the bed levelling started acting strange. Mainly, and this is fairly consistent, it gets to the end of the bed level and tells me the BL touch failed to deploy. This seemed to happen after an upgrade of Klipper or of the Sonic Pad, although I can't be sure about that.I figured out my issue. I had a custom PROBE_CALIBRATE gcode_macro that I made which turned out to be the cause of the issue so I deleted the macro and the problem went away.Installed Klipper on Ramps 1.4- BLTouch not working. All was working fine prior. Arduino Mega 2560 +RAMPS 1.4, OctoPrint, Raspberry Pi3. Its a genuine BLTouch (not 3.1) Probe does not deploy, but does during self test at power on. When i run a G28, it homes X and Y and fails on Z due to not deploying probe.A warningbefore you start: Avoid touching the BL-Touch pin withyour bare fingers, since it is quite sensitive to finger grease. Andif you do touch it, be very gentle, in order to not bend or pushanything. Hook up the BL-Touch "servo" connector to a control_pin according tothe BL-Touch documentation or your … See moreAn airbag fully deploys at a speed of about 60 to 186 miles an hour upon impact. Comparatively, this is the top speed of Japan’s Shinkansen Bullet Train. The bag is completely operational in about 0.03 seconds.See the PROBE command for details on the optional probe parameters. See the MANUAL_PROBE command for details on the SPEED parameter and the additional commands available while the tool is active. Please note, the PROBE_CALIBRATE command uses the speed variable to move in XY direction as well as Z. Z_OFFSET_APPLY_PROBE¶I think the clicking sound comes from the fact that the BLTouch automatically tries to re-deploy, that's built in in the probe and not somehting you can configure. The Klipper code then pulls it up, but it might be just a little bit too slow, so it already starts re-deploying when it's done. That should probably not matter other than the sound.BL Touch V3.1 Start up = klick klack red led I can run commands pin_down / pin_up / self_test so everything looks OK G28 with printhead in position probe goes down (blue) then up (red) and after that nothing happens parts from my log file (as a whole log can not be uploaded) [bltouch] sensor_pin = ar2 control_pin = ar6 x_offset = -39.1 y_offset = …Nov 19, 2021 · JJPrinsloo commented on Nov 19, 2021. 👍 1. Verify wiring. Use different sensor pins. Usually endstop pins will work. Try with pull-up (^) or without for the sensor pin. Maybe obvious: Make sure then pin does not hit the bed during the BLTouch startup sequence. Startup issue. The z_offset is the distance between the nozzle and bed when the probe triggers. The Klipper PROBE_CALIBRATE tool can be used to obtain this value - it will run an automatic probe to measure the probe's Z trigger position and then start a manual probe to obtain the nozzle Z height. The probe z_offset will then be calculated from these measurements.You can test deploying and reacting of the probe with gcodes, Bltouch_gcodes.png. It is also possible your not using SERVO0 of your controller, in which case you need to tell Marlin which servo the bltouch is plugged into by setting Z_PROBE_SERVO_NR 2)Triggering the bltouch doesn't stop the axis.A spare Allen key is used with an endstop switch to make a probe that’s deployed and stowed by turning the key 90 degrees. You can either deploy and stow the key manually or configure movements that bump the key against some fixed point. Options for this type of probe are included in the delta example configurations that come with Marlin.Klipper plugin for dockable probes . This document is meant to describe behavior related to dockable probes. These probes are typically microswitches mounted to a printed body …

next step is to deploy the probe, and i see an unexpected movement : the bed level up to probe, during the movement to the deployment position (the movements mix at very low speed) even if the probe fire a trigger event, the G28 Z is not ended. I think Activate_Gcode does not support motion management to enable the output of …. Kimono rule 34

klipper deploy probe

The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions). Unfortunately, too many people have opened tickets without providing the log.Skr v2 BL Touch issue. I got the firmware flashed and it connects to octo. The bltouch does the deploy/stow routine on power up. However, when running a g28 the probe deploys, then stows, without lowering the z to touch the bed and I get “failed to verify probe is raised”. Because it seems to do the correct self test at power up I think it ...Getting Klipper setup on Ender 3 with 4.2.7 board and BLTouch 3.1. I am having trouble with the bltouch when homing. It will move to start homing and then probe wont deploy at all. I get a message of “Endstop z still triggered after retract” I’ve tried going through steps on this site (Connecting BL-Touch | klipper) but didnt work. Wires on bltouch on board are plugged in this order ...CR-Touch always triggered General Discussion. Hi, I have been printing using marlin for a couple of months now with no major issues. I figured I would give Klipper a try to further optimize my prints. When I got to the part of the guide regarding bltouch I began experiencing errors The Issue: When I type query_probe into the terminal klipper ...I had the same problem with it failing to deploy randomly and I found that the pin was sticking inside the BLtouch housing. I was able to get it working again by just touching the pin with my finger to free it. After I figured that out I removed the pin and cleaned it with isopropyl alcohol and that fixed the issue. 2.Jan 26, 2020 · The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions). Unfortunately, too many people have opened tickets without providing the log. Sep 29, 2023 · klipper Macro examples. Due to the organic and idiomatic nature of klipper, there is no standard method to deploy and retract a probe. Therefore, we offer a basic set of macros which serve as a framework for users to customize. The following macros are fundamental and will hopefully get one printing upon commissioning. During a manual probe, or any tool that uses it, you must always descend towards the bed. So, don't start the tool when the endstop is already triggered, and make sure the "xy move height" for the tool (if applicable) is configured to …At least bltouch 3.1 was released way after klipper 0.7, and if fixes were required to support it, they are not included in 0.7. I would then ensure the bltouch itself is able to deploy, retract and probe as expected before doing a DELTA_CALIBRATE that will probe multiple points. Just issue some BLTOUCH_DEBUG commands then try to probe a single ...Installed Klipper on Ramps 1.4- BLTouch not working. All was working fine prior. Arduino Mega 2560 +RAMPS 1.4, OctoPrint, Raspberry Pi3. Its a genuine BLTouch (not 3.1) Probe does not deploy, but does during self test at power on. When i run a G28, it homes X and Y and fails on Z due to not deploying probe.Aug 4, 2022 · when I test the probe with debug commands, the probe deploy and stow the pin but when the pin is deployed, the z endstop is shown as triggered. Using a bltouch 3.1 genuine also, it does not work with probe_with_touch_mode: True neither false any clue? attached log and printer config, klipper version on mcu v0.10.0-554-g9e4994cb klippy.log (114. ... The light on the bltouch is on when the probe is up and off when the probe is down. I have been following the klipper bltouch guide. The bltouch responds appropriately when issuing the "bltouch_debug command=pin_up" and "bltouch_debug command=pin_down" commands and deploys and retracts properly. When issuing the query_probe …These same offsets worked in my prior configuration where I used a Duet Wifi (without klipper). I re-measured them based on Kevin's guide and they are the same offsets.... What is also weird is if I move the nozzle to X0,Y0, and then do a 'probe', the result comes back saying my probe is at 0,0.Welcome. Klipper is a 3d-Printer firmware. It combines the power of a general purpose computer with one or more micro-controllers. See the features document for more information on why you should use Klipper. To begin using Klipper start by installing it. Klipper is Free Software. Read the documentation or view the Klipper code on github .With step distance I noticed a few things, first the mcu is mostly idle during a print, so there is room for it to process more commands. Second I experimented with some test prints and it seems like having more steps gives me a cleaner print which implies that the interpolation on the tmc2209 are not as good as Klipper sending more commands to …when I test the probe with debug commands, the probe deploy and stow the pin but when the pin is deployed, the z endstop is shown as triggered. Using a bltouch ….